E-Con System Showroom · Kit-of-Parts Component Candy Store
Every kit piece you shape in the Instrument — pulled into plain sight
Inspect the exact prefabricated Core Kits A–B supplied by MDCC TECH OPC from San Simon, Pampanga (2 factory drops, growing to A · B1 · B2 in V2 Air & V3 Water), alongside the eight Open-C architectural finish families configured in the Block Instrument by Homeqube Pte Ltd and bought direct from your chosen suppliers at ₱0 MDCC billing.
AB Core · Open-C boundary · MDCC TECH OPC supplies Core Kits A–B only (2 factory drops) — pay any Core Kit A–B in full to email your ₱0 Digital Asset Pack (unsigned; subject to document readiness) · Open-C finishes are direct-to-supplier at ₱0 MDCC · Direct owner ↔ installer settlement.
Verified Origin · Brand-Led Discovery
Author: JP Calma · Entities: Homeqube Pte Ltd & MDCC TECH OPC · Digest verified · SHA-256 9748431d393d…
Iconic Kits for the Philippines
Every phrase, kit specimen, and share link on this showroom carries first-party provenance by JP Calma (Homeqube Pte Ltd · MDCC TECH OPC, materials-only supply) so lot owners and installers share one verifiable reference.
- #CalmaBlocks
- #IconicKitsPH
- #CalmaECon
System Language · V1 Land Live, V2 Air & V3 Water Upcoming
How Core Kits A–B adapt to the realm (A · B1 · B2) while Open-C snaps on unchanged
Switch host system realms below to see how MDCC Core Kits A · B (growing to A · B1 · B2 in V2 Air & V3 Water) change across land, elevated air frames, and buoyant water decks — while direct-buy Open-C windows, doors, skins, floors, and fixtures remain universal.
V1 · Land — Grounded wall-panel core (A · B + Open-C) · Live. Core Kits A · B adapt to Land, Air, or Water (growing to A · B1 · B2 in V2 Air & V3 Water); direct-buy Open-C finishes (₱0 MDCC) snap onto every realm unchanged.
Clear stay-in-place footing boxes & non-rusting starter rods set into trenches.
Ground-slab reinforcing mesh, under-slab drain & water pipes, plus yard septic tank.
Flat-pack nested 1.2×3.0 m wall sheets, seam clips, clamp-on utility walls, roof planks & stair.
Open-C direct-buy finishes (₱0 MDCC): windows, doors, exterior finish, floors & fixtures from Open-C Library.
Interactive Kit Aisle & Storey Inspector
Filter Core Kits A–B & Open-C and toggle 1F vs 2F assembly rules
Drop 1 (Part 1) · MDCC Core Kit A Substructure · MDCC factory drop 1 of 2 (Kit A · Footings + Slab)
Kit A · Drop 1 — Footings & Formwork
Clear perforated formwork boxes and hybrid reinforcing cages that align the entire structural wall line.
- SFP · A1MDCC Core Crate Part

Plant / Site Photo Modular strip footing box
Substructure base cage inside clear perforated formwork
Hybrid reinforcing base & stem cage factory-set inside a 0.50 mm UV-stabilized clear box with Ø 50 mm air-release holes.
Drop 1 (Part 2) · MDCC Core Kit A Slab & Wet Rough-In · MDCC factory drop 1 of 2 (bundled in Kit A)
Kit A · Drop 1 (continued) — Ground Slab & Under-Slab Services
Starter L-dowels, two-way slab reinforcing mats, orange Wye sanitary trees, cold-water manifolds, and 1000 L septic vessel.
- SSC · B1MDCC Core Crate Part

Plant / Site Photo Wall starter dowel set
Factory-bent Ø 12 mm composite L-dowels tying footing to wall
Cast directly into the footing stem at 300–400 mm centres to lap seamlessly into the load-bearing wall core.
- GFM · B2MDCC Core Crate Part

Plant / Site Photo Slab reinforcing mat
Non-corrosive Ø 10 mm two-way slab-on-grade mat
1500 × 3000 mm composite bar grid set on plastic chairs over a compacted 3/4-inch crushed gravel bed.
- SGC · B3MDCC Clamped Module
Under-slab sanitary pipe group
Orange PVC Wye collector tree & fixture trap stub-outs
Complete Ø 100 mm Wye main, Ø 75 mm branches, Ø 50 mm vents, and direct built-in-trap toilet bend.
- WLPC · B4MDCC Clamped Module
Cold-water supply pipe group
PN20 fusion-welded PPR supply main & wet risers
Color-coded Ø 32 mm main feed stepping down to Ø 25 mm and Ø 20 mm risers terminating below each wet wall cassette.
- CST · B5MDCC Clamped Module
Composite 1000 L septic tank
Pre-molded three-chamber treatment tank with inspection ports
Drop-in sealed composite vessel accepting the Ø 100 mm main building drain where no municipal sewer tie-in exists.
Drop 2 · MDCC Core Kit B Bearing Shell & Cassettes · MDCC factory drop 2 of 2 (Kit B · B1 · B2 in V2/V3)
Kit B · Drop 2 — Walls, Cassettes, Slabs & Stairs
1200 × 3000 mm insulated bearing wall panels, composite U-ties, clamped service wall cassettes, ribbed slabs, and 2F stairs.
- ELB-W · C1MDCC Core Crate Part

Plant / Site Photo Load-bearing wall panel
Insulated structural core with dual welded mesh & hybrid bars
1200 × 3000 × 200 mm modular wall panel sprayed with 25 MPa structural sand-cement mortar once cassettes are clamped.
- VSC · C2MDCC Core Crate Part

Plant / Site Photo Wall shear connector set
150 × 300 × 150 mm composite U-ties transferring in-plane shear
Factory-molded non-corrosive connectors tied at 400 mm centres along corners, joints, and upper slab ring heads.
- Wet-Wall · C3MDCC Clamped Module

Plant / Site Photo Kitchen & bath service cassette
2200 × 1300 × 175 mm pre-piped wet-wall frame under lintel
Clamps flush inside a lintel-headed bearing wall pocket, carrying all factory-fixed drains, vents, and water risers.
- Utility · C4MDCC Clamped Module

Plant / Site Photo Laundry utility service cassette
1400 × 1300 × 175 mm dual-tap washer & laundry frame
Pre-piped utility wall module available in Standard or Upgraded manifold setups with Ø 100 mm drain and cold water feeds.
- Power · C5MDCC Clamped Module

Plant / Site Photo Electrical power service cassette
550 × 2800 × 175 mm full-height breaker & conduit column
Fits inside a single 1200 mm panel bay with upper breaker enclosure and factory Ø 20 mm conduits ready for pull wires.
- ERS · C6MDCC Core Crate Part

Plant / Site Photo Ribbed roof & floor slab panel
Twin-ribbed structural foam deck up to 4.0 m clear span
1400 mm wide panels seated over cured 25 MPa walls, topped with 50 mm 25 MPa concrete at 2% roof slope and waterproofing.
- ESC · C7 (2F)MDCC Core Crate Part2F Only

Plant / Site Photo Stepped stair flight panel (2F)
900 mm wide insulated stair core with bottom bar troughs
Activated on 2F designs with 250 mm treads × 180 mm risers finished in 25 MPa skins (255 mm waist).
Open-C · Direct-Buy Architectural Finishes (₱0 MDCC) · Curated in Open-C Library (/partners/econ/open-c) · V1 / V2 / V3
Open-C — Eight Open-C Direct-Buy Finish Families
Windows, doors, exterior skins, 2F railings, cooling points, floors, electrical trim, and sanitary fixtures keyed directly to wall slots via Receptor ABI v1 — curated in Open-C Library and bought direct from your chosen suppliers.
- WINDOW-1..3 · D1Open-C Slot · ₱0 MDCC

Plant / Site Photo Windows · Type 1–3 × Size A–Z
Fixed Protruded · Fixed Flush · Operable Sliding / Awning
Decoupled window family matching precut shell Size A–Z bands (0.4 m to 2.4 m wide); Type 3 covers operable egress.
- DOOR-1..4 · D2Open-C Slot · ₱0 MDCC

Plant / Site Photo Doors · Type 1–4 × Size A–Z
Exterior · Interior · Bathroom · Primary Egress Main Door
Floor-anchored leaf packs bound by width ≥ 750 mm (2.1 m standard height); Exterior & Main types include weather seals.
- SKIN-1..3 · D3Open-C Finish · ₱0 MDCC
Exterior skin · Type 1–3
Type 1 Permaplast · Type 2 Stone Skin · Type 3 Metal Clad
Polymer bonding coat, chosen architectural cladding or stone layer, and breathable UV-resistant water-repellent sealer.
- RAILING-1 · D4 (2F)Open-C Slot · ₱0 MDCC2F Only
Modular guard & stair railing (2F)
Safety guard pack for 2F stair voids & upper decks
Hidden cleanly in 1F houses; activates on 2F houses with ≥ 1,000 mm guard height and < 100 mm clear bar gap.
- AIRCON-1..2 · D5Open-C Slot · ₱0 MDCC
Aircon · Type 1 Split / Type 2 Window
Ø 65 mm multi-split sleeve OR transom window AC kit
Type 1 leaves bearing piers intact via Ø 65 mm sleeve; Type 2 integrates cleanly above Window Type 3 or a ≥ 400 mm pier.
- FLOOR-1..2 · D6Open-C Finish · ₱0 MDCC
Interior floor · Type 1–2
Type 1 Epoxy Cement · Type 2 Stone Tiles (R10/R11 wet)
Levelling coat, seamless sealed epoxy-cement or slip-rated stone tiles laid at 1:100 fall toward wet floor drains.
- ELEC-1 · D7Open-C Slot · ₱0 MDCC

Plant / Site Photo Electrical trim · ELEC-1
Luminaires · switches · convenience & 20A AC outlets
Unbundled electrical terminal pack scaling automatically with room count, power cassette circuits, and aircon choices.
- SANITARY-1..3 · D8Open-C Slot · ₱0 MDCC
Sanitary systems · SANITARY-1..3
Lavatory · Water Closet (305 mm lock) · Bath & Kitchen Trim
Unbundled wet fixture sets across 10 curated finishes per type, docked 1:1 to factory rough-in stub-outs on Kit B.
Plant Photography & Twin Utility Variants
Real cages, composite L-dowels, and pre-piped service cassettes
Inspect actual assembly photographs from V1 field builds and factory cassette setups in San Simon, Pampanga.
Kit A Substructure & Ground Slab Strip

Kit A clear perforated footing formwork box with hybrid rebar cage on compacted trench
Kit B Clamped Service Cassette Tiers

Pre-plumbed galvanized stud cassette ready to clamp flush inside any 200 mm bearing wall pocket.
Open-C Receptor Precision · Size A–Z (400 mm Grid · Receptor ABI v1)
26 Modular Aperture Bands & 3 Exterior Architectural Skins
Select any aperture band from Size A to Size Z on the 400 mm shell grid to inspect its width × height, lintel threshold (1,200 mm), and door minimum rule for your direct-buy Open-C suppliers.
Door slots bind by width ≥ 750 mm at 2.1 m height (Main ≥ 900 mm) (750 × 2100 mm) · 3 Window types · 4 Door types · 2 Floor finishes
Three Exterior Skin Finishes (Open-C Type 1–3 · Direct-Buy)
Polymer-modified architectural render over cured 25 MPa wall
Bonded natural stone veneer
Ventilated metal cladding + furring sub-girts + deep drip jamb flashing
AB Core · Open-C Architectural Boundary
Direct-Buy Architectural Finishes · Spec-Matched to A–B
V1 · Land (Kit A · Kit B) evolves to Kit A · Kit B1 · Kit B2 in V2 · Air & V3 · Water — the engineered factory core supplied by MDCC TECH OPC.
MDCC TECH OPC supplies Kit A · Kit B (materials only · 2 factory drops) — your engineered structural core.
Not a hardware warehouse — every finish is checked against your house openings, wall piers, and plumbing rough-ins.
Full E-Con fit verification, lintel checks, and drawing integration remain built in for every direct-buy finish.